The product

The modular data center, end to end.

Sustainable Data Center technology provider whose modular solutions help eliminate community pushback and excessive burden on the grid.

Palais modular data center modules, chillers and coolant piping

Capacity on demand

Scalable

Provides scalable modular systems up to 10MW brought online in less than 9 months*

  • Start with the load you can fill today — from 40 kW to a full megawatt block.
  • Add identical modules as demand grows, without redesigning the hall.
  • One qualified design, repeated, so every expansion is faster than the last.

*Ready time assumes site, permits and other constraints are ready.

Configurations

Choose the block, not the building.

Every configuration ships with power, cooling, white space and controls integrated. Nominal values; final ratings are confirmed at quotation.

40–100 kW

Pavilion

A complete data center in one enclosure

Self-contained, weatherproof and secure. For a first phase, a satellite site, or capacity that has to arrive before a building exists.

IT load
40–100 kW
Racks
2–14
Form
Single transportable enclosure
Best for
Edge, first phase, interim capacity
Get a quote →

0.4–3.8 MW

Citadel

Containerized, liquid-cooled data hall

Power, direct-to-chip cooling and IT in ISO-format modules, with over 80% of assembly and testing completed in the factory.

IT load
0.4–3.8 MW
Racks
3–28 AI racks
Form
ISO and custom container modules
Best for
AI clusters, phased build-outs
Get a quote →

1–10 MW

Atrium HD

High-density modular AI campus

Designed around liquid-cooled GPU pods. Data halls, power and heat rejection engineered together, then repeated module by module.

IT load
1–10 MW
Rack density
100+ kW per rack
Form
Multi-module campus
Best for
AI and HPC at scale
Get a quote →

*Ready time assumes site, permits and other constraints are ready.

Specification

What a Palais deployment delivers.

One system specification covering the modules, the liquid loop and the heat rejection plant.

Labeled isometric diagram of a Palais deployment: IT rack module, power module, energy storage module, air-cooled chillers and the primary-side fluid network.
The system described below, drawn as built: IT rack module, power module, energy storage module, air-cooled chillers (2+1) and the primary-side fluid network that ties them together.
IT load per deployment40 kW to 10 MW
Rack densityUp to 100+ kW per rack, liquid-cooled
CoolingDirect-to-chip liquid, rear-door and fan-wall air
PowerN, N+1 or 2N modular UPS and switchgear
Energy targetPUE 1.15–1.25 with warm-water loops
Water useWaterless heat rejection available
Lead timeUnder 9 months to energised capacity*
DeliveryFactory-tested modules, one point of responsibility

*Ready time assumes site, permits and other constraints are ready. Rack densities are per configuration; 3 standard configurations are listed above.