Modular data centers · 2026 / 27

Up to 10 MW, online in less than nine months*

Sustainable Data Center technology provider whose modular solutions help eliminate community pushback and excessive burden on the grid.

*Ready time assumes site, permits and other constraints are ready.

Palais modular data center modules connected to a chiller plant by red and blue coolant piping

Capacity on demand

Scalable

Provides scalable modular systems up to 10MW brought online in less than 9 months*

  • Start with the load you can fill today — from 40 kW to a full megawatt block.
  • Add identical modules as demand grows, without redesigning the hall.
  • One qualified design, repeated, so every expansion is faster than the last.

*Ready time assumes site, permits and other constraints are ready.

Why modular

The fastest way to capacity is the one nobody objects to.

Fewer megawatts requested, a smaller footprint and a shorter build. Modular is how a data center gets built in 2026.

Sited without a fight

A smaller footprint, lower profile and quieter plant mean fewer objections from the neighbours and the planning board.

A lighter load on the grid

Warm-water cooling and staged, modular power mean less interconnection capacity requested and less time queued for it.

Capacity in months, not years

Factory build runs in parallel with site work, so the critical path is shorter from the first order to the first rack.

Grow in megawatt blocks

Start at the load you can fill today and add identical modules as demand arrives, instead of overbuilding on day one.

Sustainable by design

Containment, free cooling and closed liquid loops cut energy and water use without a premium on the equipment.

Proven before it ships

Every module is assembled, wired, piped and load-tested in the factory, with one party accountable through start-up.

One product, whole system

Everything inside the module arrives tested.

Power, cooling, white space, controls and commissioning are engineered together and shipped as one deliverable — no interface gaps to administer on site.

Isometric diagram of the Palais modular data center: IT rack module, power module, energy storage module, air-cooled chillers and the primary-side fluid network of red and blue pipes.
One Palais deployment: IT rack modules, power and energy storage modules, air-cooled chillers (2+1) and the primary-side fluid network — assembled and tested before it leaves the factory.
L1

Power

UPS, switchgear and batteries, integrated and tested

L2

White space

Racks, containment, busway and cable trays

L3

Liquid loop

CDUs, manifolds, cold plates and prefabricated pipe

L4

Heat rejection

Dry coolers and chillers sized for warm-water loops

L5

Controls

Monitoring, metering and remote operations

L6

Commissioning

Load banks, flush and fill, proven before shipment

Configurations

From a single enclosure to a 10MW campus.

Three sizes, one design language. Start where you are and scale without starting over.

40–100 kW

Pavilion

A complete data center in one enclosure

Self-contained, weatherproof and secure. For a first phase, a satellite site, or capacity that has to arrive before a building exists.

IT load
40–100 kW
Racks
2–14
Form
Single transportable enclosure
Best for
Edge, first phase, interim capacity
Get a quote →

0.4–3.8 MW

Citadel

Containerized, liquid-cooled data hall

Power, direct-to-chip cooling and IT in ISO-format modules, with over 80% of assembly and testing completed in the factory.

IT load
0.4–3.8 MW
Racks
3–28 AI racks
Form
ISO and custom container modules
Best for
AI clusters, phased build-outs
Get a quote →

1–10 MW

Atrium HD

High-density modular AI campus

Designed around liquid-cooled GPU pods. Data halls, power and heat rejection engineered together, then repeated module by module.

IT load
1–10 MW
Rack density
100+ kW per rack
Form
Multi-module campus
Best for
AI and HPC at scale
Get a quote →

Talk to us

Tell us the load and the date you need it.

We will come back with a reference design, a site plan and a delivery schedule for the modular system that fits.

Request a quote